1.1.17 What does the operating mode S6 mean for circular saw motors?

Operating mode S6, duty cycle ED=40%, cycle time 10mins. The motor may run for 4 minutes under load and must then cool down for 6 minutes at no load, otherwise overheating is likely to occur. A short-term operation can be converted into continuous operation.

 

Here is a corresponding overview of the nominal operating modes:

 

Abbreviation

Description

M-/P- Diagram

Required additional details

S1

Continuous operation with constant load

 

 

S2

Short-term operation

 

  • Load duration

S3

Periodic intermittent operation

 

  • Rel. ED in % (related to 10 min)

S4

Periodic intermittent operation with influence on the start-up process

 

  • Rel. ED in %
  • Switching cycles per hour
  • Moment of inertia
  • Run-up and run-down time

S5

Periodic intermittent operation with influence on the star-up process and electrical braking

 

  • Rel. ED in %
  • Switching cycles per hour
  • Moment of inertia
  • Run-up and run-down time

S6

Uninterrupted periodic operation

 

  • Rel. ED in % (related to 10 min)

S7

Uninterrupted periodic operation with electrical braking

 

  • Switching cycles per hour
  • Moment of inertia
  • Run-up and run-down time

S8

Uninterrupted periodic operation with load and speed changes

 

  • Switching cycles per hour
  • Moment of inertia
  • Run-up and run-down time

S9

Operation with non-periodic load and speed changes

 

  • Switching cycles per hour
  • Moment of inertia
  • Run-up and run-down time

S10

Operation with single constant loads