Please Please register or login to see the price.
Close filters
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
2 From 9
No results were found for the filter!
ATEX- Motor ASA 160M-7.5 kW 6pol-B3 ATEX- Motor ASA 160M-7.5 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 7,5kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 140 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor= 3...
ATEX- Motor ASA 180L-15 kW 6pol-B3 ATEX- Motor ASA 180L-15 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 15,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 225 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 200La-18.5 kW 6pol-B3 ATEX- Motor ASA 200La-18.5 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 18,5kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 285 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 200Lb-22 kW 6pol-B3 ATEX- Motor ASA 200Lb-22 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 22,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 300 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 225M-30 kW 6pol-B3 ATEX- Motor ASA 225M-30 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 30,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 350 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 250M-37 kW 6pol-B3 ATEX- Motor ASA 250M-37 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 37,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 430 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 280S-45 kW 6pol-B3 ATEX- Motor ASA 280S-45 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 45,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 560 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 280M-55 kW 6pol-B3 ATEX- Motor ASA 280M-55 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 55,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 690 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
ATEX- Motor ASA 315MX-110 kW 6pol-B3 ATEX- Motor ASA 315MX-110 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 110,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 1110,o kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature...
ATEX- Motor ASA 315LX-132 kW 6pol-B3 ATEX- Motor ASA 315LX-132 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 132,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 1110 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature...
ATEX- Motor ASA 315LY-160 kW 6pol-B3 ATEX- Motor ASA 315LY-160 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 160,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 1210 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature...
ATEX- Motor ASA 315S-75 kW 6pol-B3 ATEX- Motor ASA 315S-75 kW 6pol-B3
Flameproof electric motor according to ATEX 2G Ex / d IIC T4, Power= 75,0kW, Speed​​= 1000 rpm, Voltage= 3 x 400/690 Volt, Weight= 790 kg, Frequency= 50 Hz, Paint= RAL 5010 (gentian blue), Degree of protection= IP55, Temperature sensor=...
2 From 9

ATEX Three-Phase Motors

On this page, you will find a selection of explosion-proof motors in grey cast iron. These are available in sizes 71-315 with the following power output capacities: 0.09kW, 0.18kW, 0.25kW, 0.37kW, 0.55kW, 0.75kW, 1.1kW, 1.5kW, 2.2kW, 3kW, 4kW, 5.5kW, 7.5kW, 11kW, 15kW, 18.5kW, 22kW, 30kW, 37kW, 55kW, 75kW, 90kW, 110kW, 160kW, 200kW, 220kW, 250kW, 280kW and 315kW. These motors are available in rotation speeds, i.e., motors with 2, 4, and 6 poles. All the listed EX. motors are equipped with a pressure-resistant closure and comply with the relevant directives.

Sizes 80-225 are available in II 2G Ex db IICT4 Gb
Sizes 250-355 are available in II 2G Ex db IIBT4+H2 T4 Gb 



Explosion-proof ATEX motor structure

Explosion-proof ATEX Motor structure


Important Note on the ATEX Version 

The company that is operating the motor is responsible for determining which outdoor areas or enclosed spaces are deemed as potentially explosive atmospheres according to general regulations. If there is any doubt about the definition of zones with explosive atmospheres, the responsible supervising authority must decide. Directive 99/92/EG - ATEX 137 (formerly ATEX 118a), Occupational Health and Safety Directive, clearly specifies the responsibilities the operator of such installations has. Directive 94/9/EG ATEX 95 is the basis for explosion-protected products (equipment directive). This directive defines the requirements for products that are in use in potentially explosive atmospheres. Electrical machines that are in operation in zones 1, 2, or zones 21, 22 can be designed with different types of ignition protection. The aim of these ignition protections is safe prevention of ignition of any explosive atmosphere present in the area where the electrical machine is in use. 

 

Ignition Protection – Flameproof Enclosure “D” 

Construction Regulation: EN 60079-1: 2007 (VDE 0170-5) Definition:
This ignition protection ensures that any parts which can ignite an explosive atmosphere are arranged in an enclosure. In the event of an explosion of an explosive mixture inside, the enclosure withstands the pressure and prevents the transmission of the explosion to the explosive atmosphere surrounding it. 

- Observation of the explosion group
- Flameproof housing
- Complying with the required gap widths and lengths
- Terminal box pressure-proof enclosure “d” or for increased safety “e”
- The temperature of the outer surface must be lower than the ignition temperature of the gases occurring in the surrounding  environment
- An explosion may occur inside the housing – it must however withstand this pressure and a flame or ignitable, hot gases must not leak to the outside through any gaps 

SEO= Atex- Motors 1.5/2,2/3/ 4/5,5/7,5/11/15KW - ATEX three-phase motors

 

Viewed