1.1.17 What does operating mode S6 mean for circular saw motors?

Operating mode S6 , duty cycle ED=40%, operating time 10 min. The motor may run under load for 4 minutes and must then cool down for 6 minutes at idle, otherwise overheating would occur. Short-term operation can be converted into continuous operation.

Here is a corresponding overview of the nominal operating modes:

Abbreviation Description M-/P-diagram required additional information
S1 Continuous operation

with constant load

Nominal operating mode-S1.JPG
S2 Short-term operation Nominal operating mode-S2.JPG
  • Load duration
S3 Periodic intermittent operation Nominal operating mode-S3.JPG
  • Relative ED in % (based on 10 min)
S4 Periodic intermittent operation

with the influence of the start-up process

Nominal operating mode-S4.JPG
S5 Periodic intermittent operation

with the influence of the start-up process and electric braking

Nominal operating mode-S5.JPG
  • rel. ED in %
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S6 Continuous periodic operation Nominal operating mode-S6.JPG
  • Relative ED in % (based on 10 min)
S7 Continuous periodic operation

with electric braking

Nominal operating mode-S7.JPG
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S8 Continuous periodic operation

with load and speed changes

Nominal operating mode-S8.JPG
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S9 Operation with non-periodic load and speed changes Nominal operating mode-S9.JPG
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S10 Operation with individual constant loads