1.1.15 What does the term "flameproof enclosure" mean for ATEX motors?

Type of ignition protection: Flameproof enclosure “d”

Building regulation: EN 60079-1:2007 (VDE 0170-5) Definition:
A type of ignition protection in which the parts that can ignite an explosive atmosphere are arranged in a housing which, in the event of an explosion of an explosive mixture inside, can withstand the pressure of that mixture and prevents the explosion from being transmitted to the explosive atmosphere surrounding the housing.

1.1.15 Was bedeutet bei ATEX-Motoren die Bezeichnung "Druckfeste Kapselung"?