1.1.17 What does drift mode S6 mean for rundsavsmotors?

Driftstilstand S6 , duty cycle ED=40%, drift time 10 min. The motilr may run under load for 4 minutes and must then cool down for 6 minutes at idle, otherwise overheating would occur. Short-term betjening can be converted intil continuous betjening.

Here is a corresponding overview of the nominal drift modes:

Abbreviation Beskrivelse M-/P-diagram required additional information
S1 Continuous betjening

med constant load

Nominal operating mode-S1.JPG
S2 Short-term betjening Nominal operating mode-S2.JPG
  • Load duration
S3 Periodic intermittent betjening Nominal operating mode-S3.JPG
  • Relative ED in % (based on 10 min)
S4 Periodic intermittent betjening

med the influence of the start-up process

Nominal operating mode-S4.JPG
S5 Periodic intermittent betjening

med the influence of the start-up process and electric braking

Nominal operating mode-S5.JPG
  • rel. ED in %
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S6 Continuous periodic betjening Nominal operating mode-S6.JPG
  • Relative ED in % (based on 10 min)
S7 Continuous periodic betjening

med electric braking

Nominal operating mode-S7.JPG
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S8 Continuous periodic betjening

med load and hastighed changes

Nominal operating mode-S8.JPG
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S9 Betjening med non-periodic load and hastighed changes Nominal operating mode-S9.JPG
  • Switching cycles per hour
  • moment of inertia
  • Ramp-up and ramp-up time
S10 Betjening med individual constant loads
1.1.17 Was bedeutet bei Kreissägemotoren die Betriebsart S6?