-
Three-phase motor MX2 801 0.55 kW- 4-pole-B35
Three-phase motor, power= 0.55 kW, speed= 4 poles, Design= B35, Shaft= 19 x 40 mm, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE2, Efficiency = 77.1%. Finish...Three-phase motor, power= 0.55 kW, speed= 4 poles, Design= B35, Shaft= 19 x 40 mm, Voltage= 3 x... -
Three-phase motor MX2 801 0.18 kW- 8-pole-B34
Three-phase motor, power= 0.18 kW, speed= 8 poles, Design= B34, Shaft= 19 x 40 mm, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE2, Efficiency = 45.9%. Finish...Three-phase motor, power= 0.18 kW, speed= 8 poles, Design= B34, Shaft= 19 x 40 mm, Voltage= 3 x... -
Three-phase motor MX2 801 0.18 kW- 8-pole-B35
Three-phase motor, power= 0.18 kW, speed= 8 poles, Design= B35, Shaft= 19 x 40 mm, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE2, Efficiency = 45.9%. Finish...Three-phase motor, power= 0.18 kW, speed= 8 poles, Design= B35, Shaft= 19 x 40 mm, Voltage= 3 x... -
Three-phase motor MS2 71P- 0.55 kW- 4-pole- B35
Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B35, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE2, Efficiency = 77.1%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B35, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MS2 71P 0.55kW- 4-pole-B34
Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B34, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE2, Efficiency = 77.1%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B34, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX3 801 0.75 kW- 2-pole-B14
Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Type= B14, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency= 50/60 Hertz, Efficiency class= IE3, Efficiency= 80.7%, Finish= RAL 5010 (Gentian Blue), Protection class= IP55,...Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Type= B14, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX3 801 0.75 kW- 2-pole-B5
Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency= 50/60 Hertz, Efficiency class= IE3, Efficiency= 80.7%, Finish= RAL 5010 (Gentian Blue), Protection class= IP55,...Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P- 0.75 kW- 2-pole- B5
Motor in reduced size, power= 0.75kW, speed= 2 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 69%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.75kW, speed= 2 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P- 0.75 kW- 2-pole- B14
Motor in reduced size, power= 0.75kW, speed= 2 poles, Type= B14, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 69%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.75kW, speed= 2 poles, Type= B14, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX3 801 0.75 kW- 2-pole-B35
Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Design= B35, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency= 50/60 Hertz, Efficiency class= IE3, Efficiency= 80.7%, Finish= RAL 5010 (Gentian Blue), Protection class= IP55,...Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Design= B35, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX3 801 0.75 kW- 2-pole-B34
Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Design= B34, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency= 50/60 Hertz, Efficiency class= IE3, Efficiency= 80.7%, Finish= RAL 5010 (Gentian Blue), Protection class= IP55,...Three-phase motor, electric motor, power= 0.75kW, speed= 2 poles, Design= B34, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P- 0.75 kW- 2-pole- B35
Motor in reduced size, power= 0.75kW, speed= 2 poles, Design= B35, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 69%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.75kW, speed= 2 poles, Design= B35, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P- 0.75 kW- 2-pole- B34
Motor in reduced size, power= 0.75kW, speed= 2 poles, Design= B34, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 69%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.75kW, speed= 2 poles, Design= B34, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 802 0.25 kW- 8-pole-B3
Three-phase motor, electric motor, power= 0.25kW, speed= 8 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 64.1%. Finish = RAL 5010 (Gentian...Three-phase motor, electric motor, power= 0.25kW, speed= 8 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P- 0.55 kW- 4-pole- B3
Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 66%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX3 802 0.75 kW- 4-pole-B3
Three-phase motor, electric motor, power= 0.75kW, speed= 4 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency= 50/60 Hertz, Efficiency class= IE3, Efficiency= 82.5%, Finish= RAL 5010 (Gentian Blue), Protection class= IP55,...Three-phase motor, electric motor, power= 0.75kW, speed= 4 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P 0.37kW- 6-pole-B14
Motor in reduced size, power= 0.37kW, speed= 6 poles, Type= B14, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 52.1%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.37kW, speed= 6 poles, Type= B14, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P 0.37kW- 6-pole-B5
Motor in reduced size, power= 0.37kW, speed= 6 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 52.1%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.37kW, speed= 6 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX3 802 1.1 kW- 2-pole-B3
Three-phase motor, electric motor, power= 1.1kW, speed= 2 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency= 50/60 Hertz, Efficiency class= IE3, Efficiency= 82.7%, Finish= RAL 5010 (Gentian Blue), Protection class= IP55,...Three-phase motor, electric motor, power= 1.1kW, speed= 2 poles, Design= B3, Voltage= 3 x 230/400 V-50 Hz, 3... -
Three-phase motor MX 71P- 0.55 kW- 4-pole- B5
Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530), Frequency = 50/60 Hertz, Efficiency class = IE1, Efficiency = 66%. Finish = RAL 5010 (Gentian...Motor in reduced size, power= 0.55kW, speed= 4 poles, Design= B5, Voltage= 3 x 230/400 V-50 Hz, 3...




















